Any thoughts? A: Usually fin-tube baseboard. To troubleshoot your heating issue… (Feb 14, 2016) Alex said:Hi - We just bought an old farmhouse in New England. It's time to get some help from a heating service technician. Simply scan your heater for a burnt wire terminal. Maintaining a free space of several inches in front of the heater will rectify this problem. I'm guessing that its bound up air but I frequently bleed the air from this last convector yet I still hear this banging noise. Since you've led the top of the radiator where are would escape and you're getting no more air That's What suggests it may be clogged or blocked. Try the search function above. I let that run for a while keeping an eye on the hose end for signs of air. I installed them coming off the return line. The wall area above our 3 year old electric baseboard heater is very hot to the touch. The water that comes out is very hot but the radiator is very cold. concrete condo, 2nd floor, baseboard heating has constant sound such as a forced air system. Also, should I have the zone's impeller ON when bleeding? Thanks! I would expect the the negative effect would not be as much, but who knows for sure. The compact, low-profile design of baseboard heaters … Then again, there are hydronic baseboard heaters that use hot water or every so often oil that’s heated by a committed boiler and dispersed just about your home. Note: make sure you allow your heater to turn cool before you start cleaning. Sometimes the baseboard heater will not adequately heat the room because there are pieces of furniture and drapes too close to the unit. I believe it is forced hot water. (Dec 8, 2014) Rob said:Hello,Having a problem in my basement heating system.Circulaing hot water with seperate t stat and pump for this area. Is there a bleed valve right on the baseboard? But if thermostat is set to 25 and the temperature at the thermostat never reaches that number then the delivery of heat to the room is inadequate; that could be any of a number of problems that depend on the kind of heat such as steam, forced hot water, or air. I agree that if heating baseboards are run along a solid masonry exterior wall then there will be some heat loss into the wall itself; A retrofit adding solid foam and drywall on the wall would improve matters but it is troublesome as the heating baseboards would have to be removed and reinstalled. Here we’ll list all the common baseboard heater problems for each of those types of heaters: • Temperature is an important consideration that can lead to damage to your baseboard heater. But it's possible that your radiator Outlet is blocked or clogged with debris such as rust flakes. It's infuriating lol. Atlanta, GA 30318 (Jan 29, 2016) Gerry said:Some of our baseboard vents keep closing on their own. Electric heat is very simple: typically a resistance-type electric baseboard, running on 240V is powered through a line-voltage thermostat that basically acts as an on-off switch in response to the thermostat setting and room temperature. It ensures the exterior of the electric baseboard heater hasn’t been maintained clean; and as a result, the heating element has begun burning dirt, mud, and rubbish, thereby generating smoke. Baseboard Heater Thermostat Temperature Control Knob Marley Fahrenheat Dayton Qmark Berko 4.6 out of 5 stars 376 14"w X 8"h Steel Return Air Grilles - Sidewall and Ceiling - HVAC DUCT COVER - White [Outer Dimensions: 15.75"w X 9.75"h] When the thermostat calls for heat, it tells the zone valve to open, allowing hot water to flow through the pipes. Heater and Heater Systems. that the circulator pump runs for that zone, or if zone valves are used, that the zone valve opens. You need an on-site electrician with an ammeter if you want to see what circuits are drawing unusual current, or you can experiment by turning off circuits and watching your electric meter spin. With system up and running again and the new motor definitely working, the zone is still not heating up. Leaks started throughout the baseboards for the circulating hot water Follow the baseboard piping, feeling for a temperature drop, to find the blockage, disconnection, or air-bound piping. When the heater hasn’t been purged for a while, air and sediment can build up. Could there be a blockage and where? Water leaking from the top of the water heater could be a sign of loose piping, or a problem with the inlet valve. I'll take a look at adding an auto bleeder and relocating my bleeder as well. mine are baseboard, 3 feet long, they have 3 tubes through with a manifold at each end. heat. Always try to apply lubricant on the valves that are present inside the baseboard heater. When you say baseboard, you have to specify if you're using hot water or electric. If hot water is definitely entering the radiator but the rest of the radiator body stays cold the radiator is either Airbound or Outlet is clock. New M. Please search InspectApedia.com for HEAT WON'T TURN OFF to see some specific diagnostic suggestions. If there are hot water baseboard heating problems If there’s air within the hydronic pipes that is reducing the pipes’ temperature, you can release the air all the way through its bleeder valve. Or see AIR BLEEDER VALVES for how to find and operate those cute little controls on baseboards (or radiators), DIAGNOSE & FIX HEATING PROBLEMS-BOILER if the boiler is just not working like it should. I have a Honeywell programmable thermostat which controls the heat delivery in the ground floor of the house. Does anyone know the approximate percent reduction in efficiency form dirty and dusty fin tube? Baseboard. Reset the breaker if it has tripped. (Jan 16, 2016) Anonymous said:The hot water baseboard registers are staying hot eventhough the thermostat is turned off. (Dec 18, 2014) Kim Bogert said:I have a horrible smell coming from a baseboard. If the electric baseboard heater is not working. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. Larry,Perhaps you can use the picture frame icon next to the comment button to attach a photo and that will help us research or will encourage other readers to reply, we had a radiator freeze this past winter, trying to find a replacement. Check if the circulator is a separate pump for this zone then you don't have a zone valve. This is regrettably widespread trouble for electric baseboard heaters. The dining room bb heater is not working at all, the rest are working fine. Plumbers may install a balancing valve on loops to fix the problem. I used orange pex with an o2 barrier to supply and return the water. Both pipes market family room and basement from the furnace are hot, yet both rooms baseboard are cold. The Board requires anyone doing renovations involving their plumbing system to install shut-offs at all entry points to the apartment in order to allow servicing without impacting other share-owners. This video will show you how to bleed trapped air from a baseboard heater. Vaughan, Ontario, L4L 5X1 HOWEVER, just beyond this valve and on the continued run the pipes remain cold. No doubt, finding your electric baseboard heater not working or warming the house like it used to do can be daunting and overwhelming. No it's not normal. You are right that if you closed the louver the baseboard piping would feel hotter. 74 Alex Avenue i cannot find this type replacements, any ideas, thank you, On 2018-01-06 by (mod) - find blocked hot water heat baseboard line. Any air in the system wants to be in that up-line so if that line has a turn somewhere, a bleeder elbow there will be helpful. Hello. On 2020-01-19 by (mod) - new baseboard sections never getting really hot. InspectApedia.com Hopefully it's just air and I'll get it out. This problem can be easy to identify by the loud noise in the system’s pipes every time water passes through them and the trapped air. The five diagnostic steps above still apply for hot water radiators, but you've got an additional advantage: there may be a radiator control valve (red circle in our photo) to check (is the radiator turned on? Thanks for the help!!! It is now fixed and everything is working EXCEPT one baseboard radiator. Upstairs i have replaced the thermostat and circulating pump. Whisper quiet operation and low surface temperatures make it ideal for bedrooms, supplemental warmth, or to replace old heaters … Try resetting and readjusting your thermostat or replace it if need be. When the issue appears to be coming from the hot water pipes only, it’s an indication that you have air in your water heater. When the baseboard is dust clogged like shown you're probably blocking at least 50% of the air flow through the heater. What else could be causing this so I can be prepared when he comes in so I don't have to have him back a third time if whatever he does this time doesn't work. The smell is strongest after bleeding the lines. As a result, it will cause the baseboard heater to also not function as you would like it to be. So the first and foremost thing you should proceed with is checking for the circuit breakers trips. No matter what type you choose, you’ll gain better control of the amount of heat each room receives. Any other thoughts? 1000/750-Watt 240/208-Volt Hydronic Electric Baseboard Heater. The foil stops the circulation of air through the fins. That's a reason to be sure to bleed the entire system and to install float type air vents at high points at the boiler and at the highest other points in the building. The pipes past both zone valves are burning hot but the baseboards are not getting hot all. But cooling down the baseboards at your end is not a good approach as the underlying problems of energy cost and waste continue. Where we refer to using aa pony pump to force air out of an air bound hydronic heating system - I might try that next. ErnestAlthough I have not come across their use in adding heating baseboards, there are plumbing techniques that permit a plumber to cut into a water filled line when the water cannot be shut off. There are countless possible reasons for noise. The next possible setback is that … Do it bit by bit until you get the desired result. Q: What sort of radiators do most people use with loop hot water heating? While hot water baseboard heaters excel in terms of energy efficiency, it has a disadvantage when it comes to heat-up time and reaching your target temperature. Seeinspectapedia.com/heat/Check_Valves_Heat.php, (Dec 9, 2014) Anonymous said:thanks for your quick response.Yes the circulator only serves this area.There are no zone control valves in the system.There are no check valves either. (Dec 31, 2015) Sal said:I had New hardwood floors installed. James the part you need is sold by heating and plumbing suppliers - it's used in normal baseboard installation to cover the butt joint of two baseboard covers. I don't understand why the rads start to get warm and then pitter out. Here's my email address: dawn201196@hotmail.com (The landlord will supply them if I can find them again.). What could be going on here?? Account & Lists ... AB Energy Saving Wall Mount Radiator Heater, Light Weight Aluminum Hot Water Radiator for Kitchen, bathroom and bedrooms(10 Section) 3.5 out of 5 stars 13. For any sound that’s more than build up air, you should need to cautiously checkup the piping and valves, usually in the company of a professional. I have a baseboard water heating system installed in the 1960s when my bungalow was built ...just like the photo (ours in grey exterior though). I can bleed the non-working baseboard radiator, and get hot water, but as soon as I stop bleeding the baseboard radiator cools back down. The compressed design of baseboard heaters allows them to fit easily against the wall near the floor and any congested areas without giving any space issues. Lex,As the whole house is on one heating zone you may simply want to reduce the heat output of the upstairs baseboards by closing their output louvers.Opening the windows not only increases your heating bills, it actually speeds the movement of warm air from downstairs to the upper floor. along with heating the house. But dust, including sooty dust, can accumulate on the fins and tubing inside the baseboard. Privacy Policy | Terms of Service | Careers. so the problem is that the system piping gets hot and the basement remains warm even though the basement stat is off or set very low. Baseboard heaters are a convenient and economical way to neutralize the loss of warmth from windowpanes and are outstanding for heating since you can easily turn them on or and off banking on which room you’re residing in. - approach to bleeding air out of baseboards. Boiler Circulation Problems | Troubleshooting Hydronic Water Loops – Richard, we have a hot water boiler and we are having problems with the circulation of the water. The Furnace is operating and heating all the rooms except family room and basement.. The basement zone works fine. Apologies for the delay. (Sept 27, 2015) Jerry said:our Parsonage has a two zone baseboard system. Or perhaps you’ve found your baseboard heater not working? I can isolate each zone if I need to. That'd be diagnostic and would suggest- inadequate amount of heat being provided in feet of baseboard or number of radiatorsorheating pipes to those rooms run through a cold space like an unheated attic or crawl areaorrecurrent air bound pipesor- an unusual rate of heat loss I'd argue for a recurrent air blockage problem first IF on bleeding air the pipes suddenly heat up; the problem is even after all that the rooms are still cool. This could be caused by various reasons. I'm not even sure how to tackle this problem - it could be my furnace (though that seemed to be in good shape when inspected twice in the last 6 months - looks like it hadn't been cleaned in many years, but we had it serviced and were told it's in good shape). Feel for heat coming from them. ), and there may be a handy air bleeder valve near the top of the radiator (blue circle in our photo). If the heat is running take a look at your baseboards. Ugh. at EMERGENCY WATER SHUTOFF VALVE In any case you're still going to need to bleed air from the system when the additional feet of baseboard have been connected. In a typical radiant heating system, hot water circulating through pipes installed in the subfloor or under it … That can turn out to both categories of heaters if your thermostat isn’t functioning as it should be. Thanks I really appreciate the advice.